Danfoss Drives – Learning the Basics of Variable Frequency Drives

Материал из Wiki
Перейти к:навигация, поиск

There is widespread use of alternating recent (AC) motors since it is far more value successful and successful exactly where pace handle and significant energy output is needed. Variable frequency Danfoss drives correctly management the velocity of a normal AC induction motor. Through the Danfoss drives, pace manage with entire torque can be attained from RPM to the highest rated speed that is previously mentioned the rated velocity at diminished torque. Variable frequency drives manipulate the frequency of output by rectifying incoming AC recent into immediate recent (DC). A voltage pulse width modulation recreates the AC present and voltage output waveform. Kinds of variable frequency drives The a few common kinds of variable frequency drives incorporate: -Current resource inversion (CSI) - is the type of variable frequency push that has regenerative power ability. In basic conditions, the CSI VFD can absorb electrical power flow again from the motor to the power supply. CSI Danfoss drives have been successfully utilized in sign processing as properly as industrial power applications. -Pulse-width modulation (PWM) - has superb enter electrical power factor due to its fastened DC bus voltage. PWM variable frequency drives are commonly utilized in industries since they do not trigger motor clogging at underneath six Hz which is the recurrent dilemma with voltage resource inversion drives. PWMs are also a lot more productive and value effective. -Voltage resource inversion (VSI) - is not broadly used by industries due to the fact of the very poor electrical power factor. Prospective problems encountered with variable frequency drives 1 of the most widespread difficulties with variable frequency drives is heating due to technique harmonics. Harmonics are irregularities in the sine wave. In an excellent power circuit world, there need to be no harmonics even so, there are techniques to mitigate harmonics. The most basic method is by utilizing a sine wave filter on both side of the Danfoss drives. An additional proven tactic that can be employed on the line facet of variable frequency drives is to place a capacitor at the widespread bus. The impedance of a capacitor that is inversely proportional to the frequency of the sign will enable harmonics to see a short through the capacitor and journey through it and disregard other masses on the bus. If harmonics are not correctly mitigated on the line aspect of the Danfoss drives, troubles on crosstalk and heating may possibly be encountered. Crosstalk indicates the signal from a single circuit is interfering with the other and this is a larger concern than overheating. Overheating can increase cooling fees but crosstalk can be extremely irritating in telecommunications. In electrical power circuitry, crosstalk can lead to overheating and frequency relay excursions. Harmonics can also cause problems on the load side because of its nature as waves. Electromagnetic waves can act like a substantial amplitude sine wave indicating a modest sum of reactance can result in huge voltage spikes. On the other hand, the capacitor connected on the load side of the variable frequency drive can also create extra problems like destroying a push. Even though the techniques work nicely, it is important to be properly knowledgeable to stay away from further issues from cropping up.